Skip to Content

Skylight Cover Systems for Fall Protection & Safe Rooftop Access in Saudi Arabia

/ Roof Top Solution / Skylight Cover System
Skylight Screens in Saudi Arabia?

*Images are for illustrative purposes. Actual product appearance and specifications may vary.

Product Overview

Why Do We Need Skylight Screens in Saudi Arabia?

  • Economically minimize the risk of falls using weak roof lights without interfering with natural daylight.
  • Four configurations of flat, domed and standing seam roofs.
  • Non-penetrating design ensures that the roof is not damaged or leaks and is safe.
  • OSHA-compliant, meeting 29 CFR 1926.501(b)(4) and 29 CFR 1910.28(b)(3)(i) safety standards.
  • The Smart design provides fall protection that is dependable and has low impact on the rooftop.
  • Applicable to industrial, commercial, and government buildings where the level of safety is high.
  • Improves the security of rooftops using resistant and safe skylight covers in diverse settings.

Safety Regulations & Engineering Standards

The Skylight Screen system is constructed to meet rooftop access and fall protection requirements in Saudi Arabia.

KSA Ready Safety Standards

Skylight Screen Requirements in Saudi Arabia

The Skylight Screen system is constructed to meet the safety requirements of rooftop access and fall protection in Saudi Arabia, providing safety certainty and eliminating the dangers of weak skylights on different rooftops.

Industrial Buildings Commercial Roofs Government Projects
Supports rooftop safety certainty, consultant approvals, and compliant skylight protection across KSA projects.
  • OSHA 29 CFR 1926.501(b)(4)
    Fall protection in the general industry.
    OSHA
  • OSHA 29 CFR 1910.28(b)(3)(i)
    Rooftop access point safety regulations.
    Access Safety
  • EN ISO 14122 Part 3
    Safety requirements for permanent roof access points and walkways.
    ISO
  • EN 13374 Class A
    Temporary edge protection system for flat roofs.
    Edge Safety
  • BS 13700:2021
    British standard permanent edge protection system.
    BS
  • HSE INDG 284
    Health and Safety guidance on roof working.
    HSE
  • AS/NZS 1170.2
    Wind load compliance for rooftop safety under KSA conditions.
    Wind Load

Technical Specifications

Category Specification Details / Notes
System Type Skylight Safety Screen Designed for rooftop fall protection over skylights
Material Hot-dip Galvanized Steel / Stainless Steel Corrosion-resistant for harsh environments
Design Non-Penetrating Compression Fit No drilling into skylight frame, prevents leakage
Load Capacity Fall Protection Rated Engineered to withstand impact loads from accidental falls
Installation Tool-Based Quick Installation Approx. 20 minutes, 2-person setup
Surface Compatibility Flat, Corrugated, Standing Seam, Low-Slope Roofs Suitable for multiple roof types
Safety Compliance OSHA 29 CFR 1926.501(b)(4), EN Standards Meets international rooftop safety requirements
Mounting Frame 6005-T6 Extruded Aluminium Rails Positioned along skylight frame edges
Frame Fasteners 5/16" Zinc-Plated Threaded Rods Includes nylon lock nuts and washers for secure fixing
Screen Wire Stainless Steel / Galvanized Steel ⌀0.187" & ⌀0.250", 4" × 4" grid for strength and visibility
Screen Clips 1" Aluminium Clips Fixed using stainless steel hex head screws
*Technical specifications may vary depending on skylight type, project requirements, and approved installation configuration.
Skylight Screen System

How Skylight Screen Systems Work for Fall Protection?

The Skylight Screen system safeguards the necessary fall protection by establishing a safe barrier around vulnerable roof lights. Its non-penetrating installation is safe and does not affect the integrity of the roof, which is why it is suitable to use with roofs of different types.

  • Fits guardrails to protect by creating a stable frontline against falls through weak roof lights.
  • Simple & non-penetrating installation does not damage the roof membrane and keeps the roof intact.
  • Provides ongoing protection by securing skylight openings while still allowing natural light to pass through.
  • Applicable to a variety of roof types including flat roofs, domed roofs and standing seam roofs.
  • Adheres to OSHA safety standards for fall prevention in rooftop work.
Skylight Screen Systems Work for Fall Protection?
Fall Protection Non-Penetrating Natural Light Access OSHA Compliant

Advantages of Skylight Safety Screens for Secure Rooftop Work

Long-Term Performance Construction
Easy Installation for Effortless Setup
Flexible Design for Various Skylight Configurations
Maintains Daylight Access
Advantages of Skylight Safety Screens for Secure Rooftop Work
Increased Worker Safety
Adherence to Safety Regulations
Easy to Maintain
Non-Penetrating Option
Long-Term Performance Construction
Easy Installation for Effortless Setup
Flexible Design for Various Skylight Configurations
Maintains Daylight Access
Increased Worker Safety
Adherence to Safety Regulations
Easy to Maintain
Non-Penetrating Option
Effective Skylight Cover Systems for Saudi Arabia
Skylight Cover Systems

Effective Skylight Cover Systems for Saudi Arabia

Hitech Barrier provides advanced skylight cover systems to minimize fall risks, while allowing daylight to enter rooftops in Saudi Arabia.

  • High-Quality Materials: Designed with durable materials to provide durability and protection.
  • Non-Penetrating Design: The skylight screens are built in such a way that they do not affect the roof integrity, but rather offer the required fall protection.
  • Low-Maintenance Skylight Protection: Offers long-lasting, low-maintenance skylight fall protection for industrial and commercial rooftops in Saudi Arabia.
  • Compliant & Safe: Adheres to OSHA and international safety standards of rooftop safety in Saudi Arabia.
  • Full Service Package: We will provide total design, site survey and installation services to your KSA skylight safety requirements.
Installation Guide

Skylight Screens Installation Process

The application of the Skylight Screen system is made in a coordinated manner that provides stability, safety and adhering to project requirements.

01

Site Survey

Assess the roof type, access paths and exact position of the skylight to install it correctly.

02

Position Marking

Locate and place important points to position the screen so that there is complete coverage of skylight openings.

03

Base Unit Placement

Install the base units in the skylight area so as to have a sturdy foundation.

04

Guardrail Fitting

Plug in the guardrails to the skylight to create a protective edge to be safe.

05

Screen Installation

Install the skylight screen and make sure to ensure its safety and that it does not compromise the integrity of the roof.

06

Secure Connections

Make sure that each part is firmly fastened together with regular tools to avoid any movement.

07

Final Safety Check

Carry out a complete check-up to ensure that the system is stable and safe.

Start Your Skylight Protection Project Today

Request a Quation — Safe Skylight Screens to ensure a reliable fall protection in Saudi Arabia

Make your roof a safer place, with durable skylight screens, a sure protection against falls and safe access throughout Saudi Arabia.

FAQs

Frequently Asked Questions


Skylight screens play a major role in preventing falls caused by weak skylights, which are often overlooked as serious hazards. They also allow natural daylight to pass through while providing reliable fall protection for high-traffic workplaces in Saudi Arabia.

These screens reduce the risk of workers falling through skylight openings by enclosing them with protective barriers. Their non-penetrating structure also preserves roof integrity while creating a safer working environment on construction sites.

Yes, skylight screens are designed to withstand the extreme heat, dust, and weather conditions of Saudi Arabia. They provide long-term protection and dependable safety in harsh environments without weakening the roof structure.

Yes, skylight screens are suitable for flat roofs, domed roofs, and standing seam roofs, making them applicable for both new and existing roofs in commercial, industrial, and residential buildings.

These screens are ideal for industrial plants, warehouses, and commercial buildings with rooftop skylights. They are also widely used on construction sites and maintenance platforms where fall protection is essential.

Yes, they comply with OSHA 29 CFR 1926.501(b)(4) and OSHA 1910.28(b)(3)(i), making them fully compliant for rooftop fall protection in Saudi Arabia and providing safe access around skylight areas.

By allowing natural daylight to continue entering the building while maintaining rooftop safety, skylight screens help reduce the need for artificial lighting, improve energy efficiency, and protect workers from fall hazards.